The S&G
©
X
03
D-Drive
lock combines ease of operation with
security and flexibility. Its advanced electronic circuit design
makes it easy to open and easy to change codes. Follow these
instructions carefully to get the best possible use from your lock.
IntroductIon
This S&G
©
X
03
D-Drive
lock is shipped from the factory in
multi-user mode with a factory master code of 1 2 3 4 5 6
#. This code can be used to open the lock and set or change
codes. You should set the lock to your own, unique master
code.
Your lock can be programmed with a management reset code
that can be used to regain control of the lock in the event the
master code is lost. The management reset code must be
programmed into the lock before the master code is changed
for the first time.
At your discretion, the lock can be set to accept a supervisor
code, up to seven different user codes, and a time delay
override code. The master code holder and the supervisor
code holder (if a supervisor code is set) are responsible
for maintaining the number of active users programmed into
each lock. The master code holder and the supervisor code
holder can create and delete user codes.
The master code is designated as code #0. The supervisor
code (if set) is designated as code #1. The user codes (if
set) are designated by user position numbers 2, 3, 4, 5, 6, 7,
and 8. The time delay override code (if set) is designated as
code #9.
Each time a button is pressed, the lock acknowledges it
by sounding a “beep,and the LED on the keypad will light
momentarily as the “beepsounds. If it does not, check your
battery (or batteries) to make sure it is fresh and connected
properly, then try again.
All codes must contain six digits or six letters. Any digit or
letter can be used as many times as you wish. For instance,
the following codes (while not recommended) will operate the
lock: 5 5 5 5 5 5 # OR J J J J J J #
All codes end with #. This signals the
lock that you have finished entering all
digits of the code.
If you pause more than 10 seconds
between button presses when entering
a code, the lock will assume you do not
want to continue, and it will reset itself
to the original code. To open the lock,
begin the code entry sequence once again from the first step.
If you realize you have pressed an incorrect button when
entering a code, press or simply pause ten seconds or more,
then begin entering your code again.
If five incorrect codes are entered in a row, the S&G
©
X
03
D-
Drive
lock will shut down for a period of ten minutes. This
is a security feature. Entering a code during this period will
result in two long error tones (braps). Pressing any buttons
during the lockout period will not affect the penalty timer.
After ten minutes, the lock should operate normally.
The lock can also go into the lockout period during
programming if it interprets an incorrect programming
sequence as five or more consecutive incorrect code entries.
If the lock emits two long error tones (braps) during repeated
programming attempts, it is in lockout mode. Wait ten
minutes, then try again.
For UL installations, the maximum number of working codes
allowed is one.
Personal data which can be directly related to a code holder,
such as a birthdate, should not be used in making up a lock
code. Avoid codes which can be easily guessed.
After the lock is changed to a new code, the lock function
must checked by locking and unlocking it several times with
the container door open. Make sure it functions correctly
before closing the door.
Note: This lock has been Listed by Underwriters Laboratories for use with the following
S&G keypad(s): 6130-2XX and 6130-3XX
© Copyright 2006, Sargent & Greenleaf
Document 630-735
Revised 7/25/06
Sargent & Greenleaf, Inc.
A Wholly Owned Subsidiary of Stanley Security Solutions, Inc.
PO Box 930, Nicholasville, Kentucky 40356 USA
Phone (859) 885-9411
Phone (800) 826-7652
FAX (859) 887-2057
FAX (800) 634-4843
Sargent & Greenleaf S.A.
9, chemin du Croset
1024 Ecublens, Switzerland
Phone +41-21 694 34 00
FAX +41-21 694 34 09
Operating instructiOns
S&G
®
Z
03
D-Drive
Multi-User Electronic Safe Lock
2005 Series
Vue de la page 0
1 2 3 4 5 6 ... 11 12

Résumé du contenu

Page 1 - Operating instructiOns

The S&G© X03 D-Drive™ lock combines ease of operation with security and flexibility. Its advanced electronic circuit design makes it easy to open

Page 2

Page 10 © Copyright 2006, Sargent & GreenleafFigure 4Step 4—Carefully slide the battery behind the keypad, into the cavity that is designed to hol

Page 4

WARRANTYSeller warrants that for one year from the date of shipment from Seller’s point of manufacture, the goods shall be free from defects in materi

Page 5

© Copyright 2006, Sargent & GreenleafPage 2to open the LockMake sure the keypad is turned counterclockwise to stop. Press the code digits or lette

Page 6

openIng the Lock ➥WIth no tIme deLayA valid code is needed to open the lock. This is how to open the lock with the original factory master code of 1 2

Page 7

changIng, creatIng, deLetIng codes ➥creatIng a management reset codeA management reset code can only be created before the lock's master code is

Page 8

➥deLetIng an exIstIng codeThe holder of the master code (position 0) can delete any other code. The master code cannot be deleted under any circumstan

Page 9

➥creatIng the tIme deLay overrIde codeThe TDO code is located in position 9. It is programmed as follows.7 4 ✽ master code or supervisor code #♪♪♪♪♪ 9

Page 10 - Battery changing instructiOns

➥canceLLIng user dIsabLe In management/empLoyee access modeIf you decide user code holders should no longer have the ability to disable the lock, perf

Page 11

InformatIon tabLes ➥determInIng your Lock’s mode of operatIonEnter 4 3 ✽The ensuing beep pattern will tell you if your lock is configured in single us

Page 12 - Sargent & Greenleaf S.A

Page 9© Copyright 2006, Sargent & GreenleafLoW battery condItIonThe S&G© X03 D-Drive™ lock uses one 9-volt alkaline battery, which is housed i